H2Nano V3 Setup Guide
H2Nano Setup - 3 minutes
Can't watch the video? Follow the steps below.
Step 1: Unbox & Inspect
- Remove H2Nano from packaging
- Check contents: bottle, USB-C cable, user manual
- Inspect for any shipping damage
Step 2: Initial Charging
- Connect USB-C cable to bottle (water-resistant port on bottom)
- Plug into any USB power source
- LED indicator shows charging status
- Full charge takes 3 hours
- You can use while charging
Step 3: First Use
- Fill 280ml container with any water (tap, filtered, RO, distilled)
- Don't overfill - leave small air gap at top
- Secure lid tightly
Step 4: Generate Hydrogen
- Press button once for 5-minute cycle (1.5 PPM)
- Press button twice for 10-minute cycle (4.7 PPM)
- LED indicator shows cycle in progress
- Device will beep when complete
Step 5: Drink Immediately
- Drink within 30 minutes for maximum hydrogen absorption
- Hydrogen dissipates quickly (like carbonation)
Step 6: Cleaning & Maintenance
- Clean electrolysis chamber every 1-3 months with citric acid
- Access maintenance video in your account
- Takes 5 minutes
Troubleshooting
LED not turning on?
- Check if battery is charged
- Ensure charging cable is connected properly
- Try different USB power source
Not producing bubbles?
- Clean electrolysis chamber with citric acid
- Ensure water level is correct
- Check for mineral buildup
Water leaking?
- Ensure lid is tightened completely
- Check gasket seal for damage
- Don't overfill container
H2Life BG6 Brown's Gas System Setup
BG6 Complete Setup - 8 minutes
Can't watch the video? Follow the steps below.
Step 1: Unbox & Inspect
- Remove BG6 from packaging
- Check contents: main unit, 2x nasal cannulas, diffusion stone, funnel, condensation trap, drain hose, DI filter, power cord
- Place unit on stable, level surface
Step 2: Water Reservoir Setup
- Use DISTILLED WATER ONLY (critical for system longevity)
- Use funnel to fill reservoir to indicated line (1,200ml)
- Install DI filter in designated slot
- Never use tap water - minerals damage PEM membrane
Step 3: Attach Condensation Trap
- Connect condensation trap to gas output port
- Ensures any water vapor is caught before reaching cannula
- Empty trap as needed during use
Step 4: Connect Nasal Cannula
- Attach nasal cannula to output after condensation trap
- Adjust cannula for comfortable fit
- Position prongs in nostrils
Step 5: Power On & Timer
- Plug in power cord (110/220v compatible)
- Press power button
- Set timer (30 minutes to 6 hours)
- System begins producing gas immediately
Step 6: Begin Therapy
- Breathe normally - hydrogen mixes with air automatically
- Start with 30-60 minutes for first sessions
- Gradually increase to 1-3 hours as desired
- Gas output: 1,200 ml/min Brown's Gas (67% H₂, 33% O₂)
Step 7: Making Hydrogen Water (Optional)
- Attach stainless steel diffusion stone to gas output
- Place stone in water container
- Run system for 10-15 minutes
- Creates hydrogen-rich water (micro-nano bubbles)
Step 8: Maintenance
- Change reservoir water every 200 hours or monthly
- Clean with citric acid every few months
- Replace DI filter as needed (when TDS monitor indicates)
- Drain condensation trap regularly
Troubleshooting
No gas output?
- Check water level in reservoir
- Ensure distilled water is being used
- Verify power connection
- Check DI filter status
Low gas output?
- Replace DI filter
- Clean PEM membrane with citric acid
- Check for mineral buildup
Water in cannula?
- Empty condensation trap
- Check trap connections
- System may have been tilted during use
HX900 Pure Hydrogen Inhaler Setup
HX900 Setup & PULSE Mode - 7 minute
Can't watch the video? Follow the steps below.
Step 1: Unbox & Inspect
- Remove HX900 from carrying case
- Check contents: main unit, nasal cannula, diffusion stone, tubing, power cord
- Place on stable surface
Step 2: Water Reservoir
- Fill with DISTILLED WATER ONLY
- Do not overfill
- Check water level indicator
Step 3: Select Mode
- Standard mode: continuous hydrogen flow
- PULSE mode: optimized interval delivery
- Toggle between modes using button
Step 4: Connect Cannula
- Attach nasal cannula to output
- Adjust for comfortable fit
- Position in nostrils
Step 5: Start System
- Power on unit
- Select desired mode (Standard or PULSE)
- System begins producing 99.95% pure hydrogen
- Breathe normally
Step 6: Dual-Use Option
- Switch to hydrogen water mode by attaching diffusion stone
- Place in water container
- Run 10-15 minutes for 1.0-1.5 PPM hydrogen water
Step 7: Maintenance
- Change distilled water regularly
- Clean system monthly with citric acid
- Replace filters as indicated
H2Life V7.0 instructional video
H2Life BG6b written instructions
H2Life BG6a written instructions
HX450 written instructions
AquaFusion H2 written instructions
H2Life BG5 written instructions
HX900 V2 manual
HX3000 Written manual
HX900 manual before 4-15-2024
H2Life BG4.1 written instruction manual
H2Life Hydrotherapy Generator for baths
H2Pro300 & 600 instruction manual
H2Nano V3 user manual
H2Pro300 & 600 instruction manual
H2Life BG4 written instruction manual
H2Pro150 with BG instruction manual
HX600 Falcon instruction manual
H2Nano V2 user and setup video
H2Life Brown’s Gas therapy machine v2.0 setup video
Keep Your Device Running Optimally
Daily
- Empty condensation trap (inhalers)
- Rinse water container (bottles)
Weekly
- Check water quality/level (inhalers)
- Inspect tubing and connections
Monthly
- Change reservoir water (inhalers)
- Clean electrolysis chamber (bottles)
- Visual inspection of all parts
Every 1-3 Months
- Deep clean with citric acid
- Replace filters as needed
- Check gaskets and seals
Watch All Setup & Maintenance Videos
Setup Videos
H2Nano Complete Setup
3 minBG6 Complete Setup
8 minHX900 Complete Setup
7 minMaintenance Videos
Cleaning with Citric Acid
5 minFilter Replacement
3 minTroubleshooting Common Issues
6 minUsage Tips
Maximizing Hydrogen Concentration
4 minBest Practices for Daily Use
5 minMaking Hydrogen Water with Inhalers
4 min